System Commands

Power OnF6 01 01 01 F9 6F
Power OffF6 01 01 00 F8 6F
Get Firmware Version ScalerF6 03 01 00 FA 6F
Set Factory ResetF6 03 06 00 FF 6F
Volume UpF6 0C 00 01 03 6F
Volume DownF6 0C 00 00 02 6F
Set Volume (0-100)F6 0C 01 **  **  6F (see notes)
Mute OnF6 02 00 01 F9 6F
Mute OffF6 02 00 00 F8 6F
CVBSF6 30 01 01 28 6F
YPbPrF6 30 01 06 2D 6F
VGA 1F6 30 01 08 2F 6F
HDMI 1F6 30 01 09 30 6F
HDMI 2F6 30 01 0A 31 6F
HDMI 3F6 30 01 13 3A 6F
HDMI 4F6 30 01 14 3B 6F
OPSF6 30 01 12 39 6F
Multi-MediaF6 30 01 0B 32 6F
OPS Power OnF6 31 01 01 29 6F
OPS Power OffF6 31 01 02 2A 6F
Freeze Mode OnF6 32 01 01 2A 6F
Freeze Mode OffF6 32 01 02 2B 6F
Blank Mode OnF6 35 01 00 2C 6F
Blank Mode OffF6 35 01 01 2D 6F
Touch Lock OnF6 36 01 00 2D 6F
Touch Lock OffF6 36 01 01 2E 6F
Remote Control Device Lock OnF6 37 01 00 2E 6F
Remote Control Device Lock OffF6 37 01 01 2F 6F
Set Contrast Value (0-100)F6 34 04  **  **  6F (see notes)
Set Brightness Value (0-100)F6 34 06  **  **  6F (see notes)
Set Sharpness (0-100)F6 34 08  **  **  6F (see notes)
Set Black Level (0-100)F6 34 0C **  **  6F (see notes)
Set Picture ResetF6 34 0D 00 37 6F

Remote Control Commands

PowerF6 40 00 01 37 6F
MenuF6 40 00 0C 42 6F
ExitF6 40 00 0D 43 6F
Cursor UpF6 40 00 0E 44 6F          
Cursor DownF6 40 00 0F 45 6F
Cursor RightF6 40 00 10 46 6F
Cursor LeftF6 40 00 11 47 6F
EnterF6 40 00 12 48 6F
Audio MuteF6 40 00 13 49 6F
Volume UpF6 40 00 14 4A 6F
Volume DownF6 40 00 15 4B 6F
Screen SizeF6 40 00 19 4F 6F
Picture ModeF6 40 00 1A 50 6F
Sound ModeF6 40 00 1B 51 6F
Sleep TimerF6 40 00 1C 52 6F
Program InformationF6 40 00 1E 54 6F
Picture FreezeF6 40 00 1F 55 6F
InputF6 40 00 20 56 6F
Discrete Input Multi-MediaF6 40 00 21 57 6F
Discrete Input VGAF6 40 00 22 58 6F
Discrete Input HDMI 1F6 40 00 23 59 6F
Discrete Input HDMI 2F6 40 00 24 5A 6F
Discrete Input HDMI 3F6 40 00 25 5B 6F
Discrete Input HDMI 4F6 40 00 26 5C 6F
OPSF6 40 00 27 5D 6F
Discrete Volume Mute OnF6 40 00 28 5E 6F
Discrete Volume Mute OffF6 40 00 29 5F 6F

Notes

Config = Bit Rate: 38400, Data Length: 8, Stop Bits: 1, Parity Bits: NONE

Setting variable commands

The following outlines the hexadecimal RS232 command structure, and how to set variable levels. We will set the volume to 50% in the example below. 

Command structure :

123456
Start Code
This is the start of the RS232 command.
Function Code
This tells the ActivPanel what function to carry out.
Device Code
This tells the ActivPanel which PCA to send the command to.
Function Data
This is the value of the command in hexadecimal format:
25% = 19, 50% = 32,
75% = 4B and 100% = 64
Check Sum
This is the value of the sum of codes 1, 2, 3 and 4 in hexadecimal format.
Stop Code
This is the end of the RS232 command.


Set Volume Command (Volume set to zero) :

123456
F60C0100036F


Set Volume Command to 50% by entering the hexadecimal code in Function Data (4). Check Sum (5) will need to be recalculated since the Function Data (4) hexadecimal value changed. 

123456
F60C0132**6F


F6 + 0C + 01 + 32 = 135. Take the last two digits (35) to complete the Check Sum. The RS232 code below will set the volume to 50%.

123456
F60C0132356F
 